DG Matrix

DG Matrix makes the Interport, a multi-port solid-state transformer that replaces the separate transformers, switchgear and power conversion equipment a large power site needs. Data center operators, industrial sites and EV charging depots use it to bring big electrical loads online without waiting years for utility upgrades. The company says the system cuts total cost of ownership by one-half to two-thirds through infrastructure consolidation.

Traction 9/10
Raleigh, United States · HQ
Founded 2022242K+ followers
  • Battery Technology
  • Energy
  • Hardware
Updated 2 days ago

Funding

Funding not disclosed

Funding rounds are not available yet.

Founders

1 founder

Haroon Inam

Co-Founder / CEO

Product

Problem

Large power users, especially AI data centers, are limited less by computing equipment than by how fast electrical infrastructure can be delivered and scaled. Utility upgrade timelines and transformer lead times can stretch for years, and conventional sites need several separate systems to connect grid power, on-site generation and storage.

Solution

DG Matrix sells the Interport, a solid-state transformer (SST) that moves power between multiple ports in one unit. Solid-state transformers switch power electronically instead of relying on the iron-core transformers used for decades. The Interport connects utility power, battery storage, distributed energy resources and on-site generation, and its software routes power between them in real time. It comes in configurations for data centers, grid-connected sites and EV fleets, including a skid that converts medium-voltage AC (12 to 34.5 kV) to high-voltage DC and a unit placed next to the computing load to absorb rapid power swings. Operators can activate large loads behind the meter, ahead of full utility build-out.

Target Audience

Operators of AI data centers and hyperscale campuses, industrial and logistics facilities, and EV charging depots.

Features

  • Connect grid power, storage and on-site generation through one unit instead of separate systems.
  • Bring large loads online in months rather than waiting on utility upgrades and transformer lead times.
  • Support data center voltage standards from 400 to 1500 VDC as rack density changes.
  • Route and filter power to manage the fast swings in demand from AI workloads.
  • Keep power flowing through multi-port redundancy with transfer times under 1 ms, according to the company.
  • Use one standardized design across multiple sites instead of redesigning infrastructure at each one.